Abstract
We tested whether rats treated with the sigma1-receptor ligand, (+)-pentazocine, during transient focal ischemia would have a smaller volume of postischemic brain infarction than rats treated with the nonspecific opioid-receptor ligand (-)-pentazocine. Rats underwent focal cerebral ischemia using the filament occlusion technique for 2 h, followed by 22 h of reperfusion. Rats received (+) or (-)-pentazocine (n = 9 each group) at a dose of 2 mg x kg(-1) x h(-1) by continuous intravenous infusion from 1 h of ischemia to 22 h of reperfusion. Triphenyltetrazolium-determined infarction volume of ipsilateral striatum ([+]-pentazocine, 19 +/- 4 mm3, mean +/- SEM; [-]-pentazocine, 44 +/- 5 mm3) and cerebral cortex ([+]-pentazocine, 26 +/- 12 mm3; [-]-pentazocine, 134 +/- 29 mm3) was smaller in rats treated with (+) compared with (-)-pentazocine. Infarction volume in rats treated with (-)-pentazocine was also very similar to the infarction volume in saline-treated control rats from our previous study (striatum 44 +/- 4 mm3; hemisphere 136 +/- 27 mm3). These data indicate that sigma1-receptors may play an important role in the mechanism of injury both in cortex and striatum after 2 h of transient focal ischemia in rat.
Publication types
-
Comparative Study
-
Research Support, U.S. Gov't, P.H.S.
MeSH terms
-
Analgesics, Opioid / administration & dosage
-
Analgesics, Opioid / chemistry
-
Analgesics, Opioid / therapeutic use*
-
Animals
-
Brain / drug effects*
-
Brain / pathology
-
Cerebral Cortex / drug effects
-
Cerebral Cortex / pathology
-
Cerebral Infarction / pathology
-
Cerebral Infarction / prevention & control
-
Cerebrovascular Circulation
-
Coloring Agents
-
Corpus Striatum / drug effects
-
Corpus Striatum / pathology
-
Infusions, Intravenous
-
Ischemic Attack, Transient / drug therapy*
-
Ischemic Attack, Transient / pathology
-
Ligands
-
Male
-
Molecular Conformation
-
Narcotic Antagonists
-
Narcotics / administration & dosage
-
Narcotics / agonists*
-
Narcotics / chemistry
-
Narcotics / therapeutic use
-
Pentazocine / administration & dosage
-
Pentazocine / chemistry
-
Pentazocine / therapeutic use*
-
Rats
-
Receptors, Opioid / drug effects
-
Receptors, sigma / antagonists & inhibitors
-
Receptors, sigma / drug effects
-
Reperfusion
-
Sodium Chloride
-
Stereoisomerism
-
Structure-Activity Relationship
-
Tetrazolium Salts
Substances
-
Analgesics, Opioid
-
Coloring Agents
-
Ligands
-
Narcotic Antagonists
-
Narcotics
-
Receptors, Opioid
-
Receptors, sigma
-
Tetrazolium Salts
-
Sodium Chloride
-
triphenyltetrazolium
-
Pentazocine