Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

32 results

Filters applied: . Clear all
Results are displayed in a computed author sort order. The Publication Date timeline is not available.
Page 1
High-throughput assay for simultaneous quantification of the plasma concentrations of morphine, fentanyl, midazolam and their major metabolites using automated SPE coupled to LC-MS/MS.
Ghassabian S, Moosavi SM, Valero YG, Shekar K, Fraser JF, Smith MT. Ghassabian S, et al. J Chromatogr B Analyt Technol Biomed Life Sci. 2012 Aug 15;903:126-33. doi: 10.1016/j.jchromb.2012.07.005. Epub 2012 Jul 20. J Chromatogr B Analyt Technol Biomed Life Sci. 2012. PMID: 22841553
ASAP ECMO: Antibiotic, Sedative and Analgesic Pharmacokinetics during Extracorporeal Membrane Oxygenation: a multi-centre study to optimise drug therapy during ECMO.
Shekar K, Roberts JA, Welch S, Buscher H, Rudham S, Burrows F, Ghassabian S, Wallis SC, Levkovich B, Pellegrino V, McGuinness S, Parke R, Gilder E, Barnett AG, Walsham J, Mullany DV, Fung YL, Smith MT, Fraser JF. Shekar K, et al. Among authors: ghassabian s. BMC Anesthesiol. 2012 Nov 28;12:29. doi: 10.1186/1471-2253-12-29. BMC Anesthesiol. 2012. PMID: 23190792 Free PMC article.
Sedation during extracorporeal membrane oxygenation-why more is less.
Shekar K, Roberts JA, Ghassabian S, Mullany DV, Ziegenfuss M, Smith MT, Fung YL, Fraser JF. Shekar K, et al. Among authors: ghassabian s. Anaesth Intensive Care. 2012 Nov;40(6):1067-9. Anaesth Intensive Care. 2012. PMID: 23194237 No abstract available.
High-throughput assay for quantification of the plasma concentrations of thiopental using automated solid phase extraction (SPE) directly coupled to LC-MS/MS instrumentation.
Moosavi SM, Shekar K, Fraser J, Smith MT, Ghassabian S. Moosavi SM, et al. Among authors: ghassabian s. J Chromatogr B Analyt Technol Biomed Life Sci. 2016 Dec 1;1038:80-87. doi: 10.1016/j.jchromb.2016.10.038. Epub 2016 Oct 27. J Chromatogr B Analyt Technol Biomed Life Sci. 2016. PMID: 27802918
32 results