Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

164 results

Filters applied: . Clear all
Results are displayed in a computed author sort order. The Publication Date timeline is not available.
Page 1
The use of error and uncertainty methods in the medical laboratory.
Oosterhuis WP, Bayat H, Armbruster D, Coskun A, Freeman KP, Kallner A, Koch D, Mackenzie F, Migliarino G, Orth M, Sandberg S, Sylte MS, Westgard S, Theodorsson E. Oosterhuis WP, et al. Among authors: armbruster d. Clin Chem Lab Med. 2018 Jan 26;56(2):209-219. doi: 10.1515/cclm-2017-0341. Clin Chem Lab Med. 2018. PMID: 28796637 Free article.
Preface.
Westgard JO, Armbruster D, Westgard SA. Westgard JO, et al. Among authors: armbruster d. Clin Lab Med. 2017 Mar;37(1):xiii-xvii. doi: 10.1016/j.cll.2016.12.001. Clin Lab Med. 2017. PMID: 28153374 No abstract available.
Accuracy controls: assessing trueness (bias).
Armbruster D. Armbruster D. Clin Lab Med. 2013 Mar;33(1):125-37. doi: 10.1016/j.cll.2012.10.002. Epub 2012 Dec 20. Clin Lab Med. 2013. PMID: 23331733
Defining acceptable limits for the metrological traceability of specific measurands.
Bais R, Armbruster D, Jansen RT, Klee G, Panteghini M, Passarelli J, Sikaris KA; IFCC Working Group on Allowable Error for Traceable Results (WG-AETR). Bais R, et al. Among authors: armbruster d. Clin Chem Lab Med. 2013 May;51(5):973-9. doi: 10.1515/cclm-2013-0122. Clin Chem Lab Med. 2013. PMID: 23525873
A global multicenter study on reference values: 1. Assessment of methods for derivation and comparison of reference intervals.
Ichihara K, Ozarda Y, Barth JH, Klee G, Qiu L, Erasmus R, Borai A, Evgina S, Ashavaid T, Khan D, Schreier L, Rolle R, Shimizu Y, Kimura S, Kawano R, Armbruster D, Mori K, Yadav BK; Committee on Reference Intervals and Decision Limits, International Federation of Clinical Chemistry and Laboratory Medicine. Ichihara K, et al. Among authors: armbruster d. Clin Chim Acta. 2017 Apr;467:70-82. doi: 10.1016/j.cca.2016.09.016. Epub 2016 Sep 22. Clin Chim Acta. 2017. PMID: 27666761 Free article.
164 results